duty n. 1.義務,本份;責任;職責,職務,職能。 2.忠節,孝順;恭敬,尊敬,敬意;義,誼。 3.稅,關稅;【機械工程】功;能率;灌溉率;負荷,生產量;工作狀態。 4.【軍事】任務,勤務;兵役;【宗教】禮拜,(修行的)功課。 5.〔口語〕(原指小孩的)拉屎。 one's maternal duty 做母親的本份。 postmen's duties 郵遞員的職責。 filial duty 做女兒的義務。 That's no part of my duty. 那不是我管的事。 on radar duty for two years 當兩年雷達兵。 duty call 禮節性拜訪。 customs duties 關稅。 export [import] duties 出口[進口]稅。 After graduation, he began his duty. 他畢業后開始服兵役。 be in duty bound to (do sth.) 有義務(做某事)。 do duty as [for] 代…用,當…用 (bookcases that do duty as room dividers 當分隔房間墻壁的書柜)。 do [perform] one's duty 1. 盡義務,盡職;盡(友)誼。 2. 服兵役。 duty of water 一定區域內某種作物所需灌溉的水量。 fail in one's duty 失職。 off duty 在工作時間外,不值班,不值勤;下班 (go[come] off duty 下班)。 on duty 在工作時間內,值班,值勤;上班 (go on duty 上班)。 pay [send] one's duty to 對…表示敬意。 take sb.'s duty 替代某人的工作。
So the reforming of cscs will play an important role to implement no operator on duty 因此計算機監控系統的改造對實行無人值班起著極其重要的作用。
To implement the operation dispatch center mode - a new no operator on duty management mode in gehp will certainly further impr 實施運行調度中心模式- -一二江電廠無人值班管理新模式,必將進一步提高葛洲壩電廠的運行管理水平,優化長江電力股份公司人力資源配置,提高企業經濟效益。
In allusion to the running actualities of the operation management mode in gezhouba erjiang hydropower plant ( gehp ) , this paper analyzed its problems , and advanced a subject of research on no operator on duty in gehp 本文針對二江電廠運行值班管理模式運作現狀,分析了這一運行值班管理模式運作中存在的問題,提出了在二江電廠開展無人值班研究的課題。
So it is very indispensable and significant to develop the study - no operator on duty in gehp , with the exiting operation manpower resource in cypc to supervise more generator assets and bring them into maximal economic benefits 因此在二江電廠開展無人值班研究工作,用長江電力股份公司內現有的運行人力資源管理更多的發電資產,使其發揮最大的經濟效益是非常必要也非常有意義的。
Along with the fast development of electric power system and the formed application of computer and network technology , the application level of computer supervision & control technology in hydropower plant has fully increased . hydropower plants have come into an age of full computer supervision & control in our country ; the operation management mode of hydropower plants accordingly has been changed into " no operator on duty " ( few operators in attendance ) mode , all of which have created qualifications to realize no operator on duty 隨著電力系統的飛速發展和計算機技術、網絡技術的成熟應用,水電廠計算機監控技術應用水平全面提高,使得我國水電廠已進入全計算機監控時代,水電廠的運行值班方式也隨之發生了改變,實現了“無人值班” (少人值守)運行管理模式,為實現無人值班創造了條件。
This paper fully analyzed and discussed the progressive process of hydropower plant operation mode , the development process and trend of cscs ; simply introduced the regulations and demands of no operator on duty in hydropower plant ; analyzed all kinds of demand of cscs to implement no operator on duty ; in allusion to the running actualities of the operation management mode , analyzed the difficulties to implement no operator on duty in gehp ; put forward the reforming items for devices and equipment maintenance and demands of reforming of cscs to implement no operator on duty in gehp ; advanced a new concept and idea : " computer operator " and " computer operator director " ; and set up a new operation management mode - no operator on duty in gehp that is appropriate to three gorges cascade dispatch center ( tgcdc ) 本文全面分析論述了水電廠運行值班方式進步的過程和計算機監控系統的發展及其趨勢;簡要介紹了水電廠無人值班的規定和要求;分析了實行無人值班對計算機監控系統的各項要求;針對運行值班方式的現狀,分析了二江電廠實現無人值班的難點;提出了實現無人值班需配套進行的設備改造項目和適應無人值班的設備維護管理模式;重點分析了二江電廠實現無人值班對計算機監控系統改造的要求,提出了“電腦值班員”和“電腦值長”的概念和思路。建立了二江電廠在三峽梯調聯合調度模式下的無人值班管理新模式。
After simply compared the two refonning schemes of connecting the cscs of gehp to the cscs of tgcdc from technology and economy , this paper selected a reforming scheme which is most safety and economic for implementation and reforming , and meets the desire of no operator on duty operation mode and is appropriate to the desire of operation management mode that is on active service 論文最后對二江電廠計算機監控系統接入三峽梯調監控系統的兩套改造方案進行了簡單的技術經濟比較,優選出了滿足無人值班要求、適應現行運行值班管重慶大學碩士學位論文中女摘要理模式運作要求、實施系統接入和后期改造最安全、經濟的方案。
According to the desire of no operator on duty operation mode and dispatching two hydropower plants and two dams by tgcdc , and focusing on how to connect the cscs of gehp to the cscs of tgcdc to meet the technical demand of cascade dispatching , advanced the frame and network configuration of sj - 600 lcu that is appropriate to the functional desire of no operator on duty operation mode , and fully compared with the import lcu on system structure , technology capability and configuration ; and advanced two reforming schemes of connecting the cscs of gehp to the cscs of tgcdc that meet the desire of tgcdc and are appropriate to the desire of no operator on duty operation mode 根據無人值班和三峽梯調實行兩廠兩壩聯合調度的要求,圍繞著二江電廠計算機監控系統如何接入三峽梯調監控系統滿足梯級調度的技術要求,提出了適應無人值班功能要求的sj - 600型現地控制單元( lcu )裝置的構成和網絡結構,并就系統結構、技術性能和組態等方面同進口lcu進行了全面比較;提出了兩套滿足梯調要求、適應無人值班要求的二江電廠計算機監控系統接入三峽梯調監控系統的改造方案。
To implement the project of no operator on duty in the hydropower plants which had the operation management mode of " no operator on duty " ( few operators in attendance ) is the demand of state power corporation , at the same time , the demand of china yangtze power corporation ( cypc ) to implement the strategy of keeping banner cost 在已實行“無人值班” (少人值守)運行管理模式的水電廠中開展無人值班工作是國電公司的要求,同時也是實施長江電力股份公司的成本領先戰略的要求。